Capacitor

NWC5 Self-healing Shunt Capacitor

20130117161615_1


NWC5 Self-healing Shunt Capacitor

1. Edectric ratings: ≤AC1000V.
2. Application: Newly developed energy-saving product  for improvement of power factor and power quality;
3. Standards: IEC/EN 60831-19

20130111144245_1

 

 

NWC1 Self-healing Shunt Capacitor

20130117161602_1


NWC1 Self-healing Shunt Capacitor

1. Electric ratings: ≤AC1000V;
2. Application: For improvement of power factor  and power quality;
3. Standards: IEC/EN 60831-1: 1996

20130111143922_1

 

BZMJ Self-healing Shunt Capacitor

20130117161510_1


BZMJ Self-healing Shunt Capacitor

1. Electric ratings:  ≤AC1000V;
2. Application: For improvement of power factor and power quality
3. Standards: IEC/EN 60831-1:199

20130111143732_1 20130111143732_2

 

JKF8 Intelligent Reactive Power Compensation Controller

20130118093110_1


JKF8 Intelligent Reactive Power Compensation Controller

JKF8 Intelligent Low-Voltage Reactive Power Compensation Controller (hereinafter referred to as ”controller”) is a dedicated controller which can make compensations for the reactive power of low voltage distribution system.

 

 

NWKL1 Intelligent Reactive Power Compensation Controller

20130117170142_1

NWKL1 Intelligent Reactive Power Compensation Controller

It is used jointly with low-voltage shunt capacitive screen, to control the auto ON and OFF of shunt capacitor, improve the voltage quality and reduce energy losses.

Features:

·Reactive current, and composite control of power factor ensure a reliable operation under low load, thus to avoid switching oscillation.

·Real-time display of power factor and reactive current, parameter settings of current ratio, time delay, on limit, overvoltage protection threshold, and display of the operation groups.

·Automatic cycling and switching of capacitor banks and self check of loop conditions.

·With strong anti-interference capability, it can resist the single-pulse interference and 2000V group pulse interference with the common-mode voltage of 2500V, differential-mode voltage of 1000V, and frequency of 100kHz,, can also withstand 3rd, 5th and 7th harmonic interferences.

·Automatic identification of sampling polarity, eliminating the bother of non-polarized connection.

·With reactive current and power factor detection system, it can ensure accurate control in the full load range and make sure that the power factor can reach over 0.95.

·With over-voltage inverse time function, it is adaptable to the grid of high voltage.

·Able to switch over between manual operation and automatic operation modes.

·Applicable to power distribution system (rated voltage: 380V, AC 50Hz).